The MAH485/2 stud anchor and its washer are recommended for reinforcing wood-frame walls subject to uplift forces.
This towing anchor can be used in a variety of applications.
The fitting must always be used with the included US50/50/8G washers.
Product Details
Features
Material
- MAH485/2: S250GD steel with Z275 galvanization in accordance with NF EN 10346 (thickness: 2 mm),
- US50/50/8G washer (included): S235JR steel with hot-dip galvanized finish (thickness: 8 mm).
Benefits
- Narrow-width anchor suitable for 45 mm studs,
- Its dual configuration (foldable on-site) allows it to securely anchor the wood-frame wall to a parapet or concrete slab (recommended in seismic zones),
- Reinforces the connection between the stud and the bottom rail and prevents lifting,
- Washer included and pre-mounted on the bracket.
Application
Support
- Frame: timber , concrete,
- Structure: timber.
For use with
- Timber studs
Technical Data
Product Dimensions
| References | Joist Size [mm] | Product Dimensions [mm] | Joist | Flange B | Weight [kg] | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Width | A | B | C | D | E | t | Ø5 | Ø18 | ||
| Min | ||||||||||
| MAH485/2 | 45 | 484 | 53 | 55 | 12 | 40 | 2 | 23 | 1 | 0.45 |
Characteristic capacities - timber to rigid support - Minimum nailing
| References | Karakteristisk bärförmåga - Trä-betong - Delvis utspikning | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Fasteners | Characteristic capacities - Timber C24 [kN] | |||||||||||
| Joist | Flange B | R1.k - Flat | R1.k - Folded | |||||||||
| Qty | Type | Qty | Type | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
| MAH485/2 | 7 | CNA | 1 | Ø16 | min(8.7;18.7/kmod) | min(9.6;18.7/kmod) | min(11.6;18.7/kmod) | min(12.3;18.7/kmod) | min(8.7;24.6/kmod) | min(9.6;24.6/kmod) | min(11.6;24.6/kmod) | min(12.3;24.6/kmod) |
It is possible to increase the uplift capacity of the MAH485/2 by adding a strap FP40/2 or FP60/2. Please refer to the nailing pattern and technical details in the ETA.
Characteristic capcities - Timber to rigid support - Maximum nailing
| References | Karakteristisk bärförmåga - Trä-betong - Fullständig utspikning | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Fasteners | Characteristic capacities - Timber C24 [kN] | |||||||||||
| Joist | Flange B | R1.k - Flat | R1.k - Vikt | |||||||||
| Qty | Type | Qty | Type | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
| MAH485/2 | 21 | CNA | 1 | Ø16 | min(22.1;18.7/kmod) | min(24.3;18.7/kmod) | min(29.5;18.7/kmod) | min(31.4;18.7/kmod) | min(22.1;24.6/kmod) | min(24.3;24.6/kmod) | min(29.5;24.6/kmod) | min(31.4;24.6/kmod) |
It is possible to increase the uplift capacity of the MAH485/2 by adding a strap FP40/2 or FP60/2. Please refer to the nailing pattern and technical details in the ETA.
Simplified characteristic capacities - Timber to rigid support - Minimum nailing
| References | Karakteristisk bärförmåga - Trä-betong - Delvis utspikning | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Fasteners | Simplified characteristic capacities - Timber C24 [kN] | |||||||||||
| Joist | Flange B | R1.k - Platt (utvikt) | R1.k - Folded | |||||||||
| Qty | Type | Qty | Type | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
| MAH485/2 | 7 | CNA | 1 | Ø16 | 8.7 | 9.6 | 11.6 | 12.3 | 8.7 | 9.6 | 11.6 | 12.3 |
The published characteristic values are based on an instantaneous load duration and service class 2, in accordance with EC5 (EN 1995) – kmod = 1.1. For different load durations and service classes, refer to the general “Characteristic Values” table, in which the kmod coefficient can be adjusted.
Simplified characteristic capacities - Timber to rigid support - Maximum nailing
| References | Karakteristisk bärförmåga - Trä-betong - Fullständig utspikning | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Fasteners | Simplified characteristic capacities - Timber C24 [kN] | |||||||||||
| Joist | Flange B | R1.k - Rak | R1.k - Vikt | |||||||||
| Qty | Type | Qty | Type | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | CNA4.0x35 | CNA4.0x40 | CNA4.0x50 | CNA4.0x60 | |
| MAH485/2 | 21 | CNA | 1 | Ø16 | 17 | 17 | 17 | 17 | 22.1 | 22.4 | 22.4 | 22.4 |
Les valeurs caractéristiques publiées sont basées sur une durée de charge intantanée et une classe de service 2, selon l'EC5 (EN 1995) - kmod = 1,1. Pour des durées de charge et des classes de service différentes, se réferer au tableau "Valeurs Caractéristiques" général, dans lequel le coefficient kmod peut être ajusté.r.
Installation
Installation
Fixing
On concrete:
The US50/50/8G washer is supplied with the MAH485/2 anchor.
- Mechanical anchor Option 7: FM 753 EVO M16x151 stud
- Mechanical anchor Option 1: FM-753 CRACK M16x150 stud
- Chemical anchor Option 1: AT-HP resin + LMAS M16-170/20 threaded rod
On Timber :
- Ring nails: CNA Ø4.0x35 or CNA Ø4.0x50 (the number of nails to use depends on the application).
Installation
- Use only the fasteners specified for each configuration, strictly adhering to the edge distances.
- Regardless of the configuration, the US50/50/8G washer (supplied) must be used to ensure the loads specified in the table below.
Installation with strap:
- The MAH485/2 is compatible with the FP40/2 and FP60/2 perforated straps, subject to the following condition: the maximum number of fasteners on the FP strap section alone must equal the number of fasteners on the MAH + FP section.
- Refer to the nailing diagrams and technical specifications in ETE-07/0285
RECOMMENDED USE:
The use of the MAH anchor + US50/50/8G washer is recommended at the end of each wood-frame wall, at stud spacers, and adjacent to each opening. This recommendation does not replace a verification performed by a competent engineering firm.