Microsites

Microsites

POLY-GP

General Purpose Resin Mortar

Chemical anchor for use in concrete and masonry. Specially formulated for light or medium duty fixing into hollow or solid base materials.

Poly-GP300 is easy to use and fast curing, it enables good performance when used in applications such as fixing architectural steel work, cable trays, hand rails and gates.

CE Marking
CE Marking
ETA
ETA
Indoor
Indoor
Outdoor
Outdoor
Wet environnement using
Wet environnement using
Dist. bord et entraxe faible
Dist. bord et entraxe faible
POLY_GP_SSTBP_homepage_IT_it

Product Details

Images

Fixing of fence

Features

Material

  • Styrene free polyester
  • Use with Simpson Strong-Tie threaded rod (LMAS) : galvanised steel and stainless A4-70
     

Benefits

  • Fast curing.
  • Non-flammable.
  • Low odour.
  • Colour changes when cured.

Application

Header member

Hollow or solid masonry.

For Use With

  • Blinds
  • Hinges
  • Air conditioners
  • Satellite Dishes
  • Boilers

Technical Data

Références

ReferenceChemical fixings dimensions
Info product
Tun / DB nr.[mm]NOB nr.Grey colorBeige colorContent[ml]Weight[kg]Qty[pcs]
POLYGP300GB-PL---x3000.58612
POLYGP420B-PL---x4200.84212

Design resistance – Tension – NRd [kN] – Carbon steel 5.8

ReferenceChemical fixings Loads
Design resistance – NRd – Carbon steel 5.8[kN]
Non-cracked concrete
hef = 8dhef = 12d
C20/25C30/37C40/50C50/60C20/25C30/37C40/50C50/60
POLY-GP + LMAS M84.655.35.56.97.47.98.2
POLY-GP + LMAS M121010.911.61215.116.317.317.9
POLY-GP + LMAS M1614.315.416.41721.423.224.725.5

Concrete :
1. The design loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

 

Design resistance – Tension – NRd [kN] – Stainless steel A4-70

ReferenceChemical fixings Loads
Design resistance – NRd – Stainless steel A4-70[kN]
Non-cracked concrete
hef = 8dhef = 12d
C20/25C30/37C40/50C50/60C20/25C30/37C40/50C50/60
POLY-GP + LMAS M84.655.35.56.97.47.98.2
POLY-GP + LMAS M121010.911.61215.116.317.317.9
POLY-GP + LMAS M1614.315.416.41721.423.224.725.5

Concrete :
1. The design loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

 

Design resistance – Shear – VRd [kN] – Carbon steel 5.8

ReferenceChemical fixings Loads
Design resistance – VRd – Carbon steel 5.8[kN]
Non-cracked concrete
hef = 8dhef = 12d
C20/25C30/37C40/50C50/60C20/25C30/37C40/50C50/60
POLY-GP + LMAS M87.27.27.27.27.27.27.27.2
POLY-GP + LMAS M1216.816.816.816.816.816.816.816.8
POLY-GP + LMAS M1631.231.231.231.231.231.231.231.2

Concrete :
1. The design loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

 

Design resistance – Shear – VRd [kN] – Stainless steel A4-70

ReferenceChemical fixings Loads
Design resistance – VRd – Stainless steel A4-70[kN]
Non-cracked concrete
hef = 8dhef = 12d
C20/25C30/37C40/50C50/60C20/25C30/37C40/50C50/60
POLY-GP + LMAS M88.38.38.38.38.38.38.38.3
POLY-GP + LMAS M1219.219.219.219.219.219.219.219.2
POLY-GP + LMAS M1634.334.334.334.335.335.335.335.3

Concrete :
1. The design loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

 

Design resistance – Bending moment – MRd [Nm]

ReferenceChemical fixings Loads
Design resistance – Bending moment – MRd[Nm]
Carbon steel 5.8Stainless steel A4-70
POLY-GP + LMAS M815.216.7
POLY-GP + LMAS M1252.859
POLY-GP + LMAS M16133.6149.4

Concrete :
1. The design loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

 

Design resistance – hef = 80 mm (≤ M8) or 85 mm (≥ M10) – Carbon steel ≥ 4.6 / Stainless steel ≥ A2-70

ReferenceChemical fixings Loads
Design resistance – Carbon steel ≥ 4.6 / stainless steel ≥ A2-70
hef = 80 mm (≤ M8) or 85 mm ( ≥ M10)
Tension - NRd[kN]Shear - VRd[kN]
Solid Clay MasonryHollow MasonrySolid Clay MasonryHollow Masonry
POLY-GP + LMAS M61.60.82.40.8
POLY-GP + LMAS M81.60.82.40.8
POLY-GP + LMAS M121.60.82.80.8

Masonry :

 

  Compressive strength fb [N/mm²] Bulk density ρ [kg/m3]
Solid clay masonry ≥ 18 ≥ 1600
Hollow masonry ≥ 6 ≥ 900

 


1. The design resistances have been calculated using the partial safety factors for resistances stated in ETA-approval(s).
2. The recommended loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s) and with a partial safety factor for actions of γF=1.4.
3. For combined tension and shear loads or anchor groups and/or in case of edge influence, a calculation acc. TR 054, design method A shall be performed. For details see ETA - assessment(s)
4. Temperature range: -40°C/+40°C (Tmlp = +24°C)
5. Coefficiant factor β for in situ tests acc. ETAG 029 see ETA-19/0642; Annex C2
6. Displacements under service load see ETA-19/0642; Annex C2 & C3

Design resistance – Bending moment – MRd [Nm]

ReferenceChemical fixings Loads
Design resistance – Bending moment – MRd[Nm]
Carbon steel 5.8Carbon steel 8.8Stainless steel ≥ A2-70
POLY-GP + LMAS M66.49.67.1
POLY-GP + LMAS M815.22416.7
POLY-GP + LMAS M1252.88459

Masonry :

 

  Compressive strength fb [N/mm²] Bulk density [kg/m3]
Solid clay masonry ≥ 18 ≥ 1600
Hollow masonry ≥ 6 ≥ 900

 

1. The design resistances have been calculated using the partial safety factors for resistances stated in ETA-approval(s).
2. The recommended loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s) and with a partial safety factor for actions of γF=1.4.
3. For combined tension and shear loads or anchor groups and/or in case of edge influence, a calculation acc. TR 054, design method A shall be performed. For details see ETA - assessment(s)
4. Temperature range: -40°C/+40°C (Tmlp = +24°C)
5. Coefficiant factor β for in situ tests acc. ETAG 029 see ETA-19/0642; Annex C2
6. Displacements under service load see ETA-19/0642; Annex C2 & C3

 

Installation

Installation

Curing Schedule

Temperature of the anchorage base

Tbase material

Working time (Gel time)

tgel

Curing time (in dry concrete)

tcure, dry

Curing time (in wet concrete)

tcure, wet

0°C ≤ Tbase material < +10°C 20 min 90 min 3:00 h
+10°C ≤ Tbase material < +20°C 9 min 60 min

2:00 h

+20°C ≤ Tbase material < +30°C 5 min 30 min 1:00 h
+20°C ≤ Tbase material ≤ +40°C

3 min

20 min 40 min

 

• Manual Air Cleaning (MAC) for all drill hole diameters d0 ≤ 24 mm and drill holl depth h0 ≤ 10d : 
          4x blowing (hand pump)
          4x brushing (twisting motion)
          4x blowing (Hand pump)

• Compressed Air Cleaning (CAC) for all drill hole diameters d0 and drill hole depths :
          2x blowing (min. 6 bar - oil free compressed air)
          2x brushing
          2x blowing (min. 6 bar - oil free compressed air)

• Cartridge temperature (Bond material) : ≥ +20°C

 

Installation parameters – Concrete

ReferenceChemical fixings Installation data
Installation parameters – Concrete
Ø drilling diameter[mm]Maximum diameter of hole in the fixture[mm]Drilling depth (8d)[mm]Drilling depth (12d)[mm]Wrench sizeInstallation torque[Nm]
POLY-GP + LMAS M81096496138
POLY-GP + LMAS M121414961441915
POLY-GP + LMAS M1618181281922425

Spacing, edge distances and member thickness – Concrete

ReferenceChemical fixings Installation data
Spacing, edge distance and member thickness - Concrete
Effective embedment depth (8d)[mm]Characteristic spacing for hef,8d[mm]Characteristic edge distance for hef,8d[mm]Min. member thickness for hef,8d[mm]Effective embedment depth (12d)[mm]Characteristic spacing for hef,12d[mm]Characteristic edge distance for hef,12d[mm]Min. member thickness for hef,12d[mm]Min. spacing[mm]Min. edge distance[mm]
8d12d[mm]8d12d[mm]
POLY-GP + LMAS M864192961009628814412632483248
POLY-GP + LMAS M129628814412614443221617448724872
POLY-GP + LMAS M1612838419215819257628822264966496

Installation parameters – Masonry – Solid clay masonry

ReferenceChemical fixings Installation data
Installation parameters - Solid clay masonry
Ø drilling diameter[mm]Maximum diameter of hole in the fixture[mm]Depth of the drilling hole[mm]Installation torque[Nm]
POLY-GP + LMAS M687852
POLY-GP + LMAS M8109852
POLY-GP + LMAS M121414902

Installation parameters – Masonry – Hollow masonry

ReferenceChemical fixings Installation data
Installation parameters - Hollow masonry
Ø drilling diameter[mm]Maximum diameter of hole in the fixture[mm]Depth of the drilling hole[mm]Installation torque[Nm]
POLY-GP + LMAS M6127851.5
POLY-GP + LMAS M8129851.5
POLY-GP + LMAS M121614901.5

Spacing, edge distances and member thickness – Masonry – Solid clay masonry

ReferenceChemical fixings Installation data
Spacing, edge distance and member thickness – Solid clay masonry
Min. spacing[mm]Min. edge distance[mm]
scr,N = smin[mm]scr,N || = smin ||[mm]scr,N T = smin T[mm]ccr,N = cmin[mm]
POLY-GP + LMAS M6240--120
POLY-GP + LMAS M8240--120
POLY-GP + LMAS M12255--127.5

Spacing, edge distances and member thickness – Masonry – Hollow masonry

ReferenceChemical fixings Installation data
Spacing, edge distance and member thickness – Hollow masonry
Min. spacing[mm]Min. edge distance[mm]
scr,N = smin[mm]scr,N || = smin ||[mm]scr,N T = smin T[mm]ccr,N = cmin[mm]
POLY-GP + LMAS M6-250120100
POLY-GP + LMAS M8-250120100
POLY-GP + LMAS M12-250120100

Certification

Declaration of Performance (DoP)

No history available
No history available

European Technical Assessment (ETA)

No history available
No history available

Buy Online

Contact

Simpson Strong-Tie Poland

Simpson Strong-Tie Etanco P.S.A.

ul. Karczunkowska 42
02-871 Warszawa
Poland