BAN-S

X-shaped perforated stainless steel tape BAN

These tapes are used for anchoring the timber in the low load range and as a structural connection.

CE Marking
Service class 3
Stainless steel A4

Product Details

Images

Features

Material

Steel quality:
• Stainless Steel 1.4401 bzw. 1.4404 (V4A) in accordance with EN10088 standards.
• Class III corrosion resistance

Benefits

• BAN tapes are available in a thickness of 1.0 mm and 1.5 mm in various lengths.
• Also available in stainless steel execution.

Application

Header member

Wood, wood materials

Application area

• Typical applications include light ceilings and sliding doors.

Technical Data

Dimensions

Dimensions and drill holes

References Tun / DB nr. NOB nr. Dimensions [mm] Holes
A B [m] t Size Size
BAN102010S37791212122133820101Ø5Ø6,5

Product capacities

References Characteristic capacities (kN) - Timber C24
R1,k
Maximum value CNA4,0x35 CNA4,0x40 CNA4,0x50 CNA4,0x60
BAN102010S4,0/kmod1.68 x n1.83 x n2,22 x n2,36 x n

*capacity R1,k is calculated from the nails capacities but mustn’t exceed the maximum value.

n = effective number of nails in the row according to Eurocode 5 – 8.3.1.1 (8)

Product Dimensions & Performance Values (UK)

References Dimensions Holes Maximum Characteristic Values Tolerated R1,st [kN]
A [mm] B [m] t [mm]
BAN102010S20101Ø54

The maximum characteristic value tolerated under tensile load corresponds to the plate's maximum tensile strength. The fasteners must be checked separately using EN 1995-1-1. The characteristic resistance of an BAN fixing band assembly under tensile load R1.k is: Rl.k= min (R1.st; Rupper; Rlower )

Where:

R1.st: the maximum characteristic value tolerated under tensile load as specified in the table above. Rupper: the resistance of the group of fasteners in the upper wall Rlower: the resistance of the group of fasteners in the lower wall Rupper = nef.upper x Rlat.k  Rlower = nef.lower x Rlat.k

Where:

nef.upper: the effective number of fasteners in the upper wall nef.lower: the effective number of fasteners in the lower wall Rlat.k: the strength of the chosen fastener

Example: BAN094025 joining two CLT walls with an intermediate floor. The aim is to determine the fixing band's load-bearing capacity when subjected to tensile forces. The nailing pattern shown below is used. The following table provides the characteristic strength values.

 

Installation

Installation

Fixing

• A combination of perforated strips of wood takes place nails or screws CNA3,1x40 CSA4,0x30.

Buy from Distributor

No items available.

Contact

Simpson Strong-Tie Poland

Simpson Strong-Tie Sp. z o.o.

ul. Karczunkowska 42
02-871 Warszawa
Poland